6, 9
& 12 Station
Indoor & Outdoor Controller

Installation
and Programming Guide
For Models
RD-600, RD-900, RD-1200 (EXT
& INT)
|
|
|
|
|
|
1.0 Contents & Specifications
2.0 Key Features
3.0 Battery Installation (Indoor and Outdoor Models)
4.0 Indoor Model Installation
5.0 Outdoor Model Installation
6.0 Connecting the Valves
7.0 Connecting to Power
8.0 What the Buttons and Switches Do
9.0 How the Multi-Function Dial Works
10.0 "Anywhere" Programming, Fail-Safe Mode
11.0 Automatic Operation, Step by Step
12.0 What the LCD Displays Mean
13.0 Documenting Your Auto Operation
14.0 Semi-Auto & Manual Operation
15.0 Troubleshooting the System
16.0 FCC Notice
|
|
| 1.0 Contents & Specifications |
|
|
Congratulations. You have purchased the easiest-to
use landscape control system available today. Although
it is possible to install and program your Rain Dial®
controller with little or no instructions, we strongly
recommend that you read this guide first.
Your controller kit contains:
Outdoor models
Controller
2 keys
3 mounting screws
Instruction guide
Mounting template
|
Indoor models
Controller
Plug-in transformer
3 mounting screws
Instruction guide
Mounting template
|
Specifications
Input: 120VAC, 60Hz, .5 amp. (NOTE: 220 or 240 VAC, 50 Hz available.)
Output: 24VAC at 1.25 amp total maximum output; .5 amp. / station max.
Operating temperature range: 32°F to 140°F.
Battery back-up: One 9 volt alkaline or NiCad (supplied by user)
|
|
|
|

Modular design allows...
-Easy access to valve wiring terminals & battery
-Simple snap-out removal of module for convenient "anywhere"
programming or service without disturbing installation
-Easy modular upgrade to as many as 12 stations
Short circuit detection overides an electrical malfunction of a valve,
identifies it, and allows the other valves to water.
Default "fail-safe" program runs all valves for 10 minutes daily in case of
program loss
Rugged, weather resistant, lockable case comes with 2 keys
(outdoor models only)
3 programs for different watering requirements such as trees, lawn and flower
garden.
3 start times for each program, if desired
"Skip day" scheduling for interval watering from 1 to every 15 days
Fully automatic or semi-automatic operation
Manual operation allows user to select valve(s) and watering duration
Display shows current operation, including time of day
Live programming allows program to be set or even changed at any time,
even during watering.
Off (or rain) setting stops all watering cycles without disturbing programs
Battery back-up saves programs and keeps time during remote
programming or power outage.
|
|
|
|
|
Installing the Battery (Indoor and Outdoor Models)
Open the door to your controller, then pop the control module
up by flexing the inside tab to your right. The battery compartment
is located at the top in the back of the modul. Open it.
Insert a standard 9 volt alkaline battery onto the clip.
The battery will preserve your program and run the clock
during a power outage, but it will not operate the valves.
|
|
| 4.0 Indoor Model Installation |
|
|
Installing the Indoor Model Controller
Using the mounting template, locate your Rain Dial indoor
model in an area protected from weater - such as a garage - within
5 feet of a standard (120 volt U.S.) electrical outlet. NOTE: Do
not install on the same circuit as a high power user such as a
refrigerator, garage door opener or air conditioner. Insert a
#10 screw into a wall stud, leaving about 1/4" exposed to slip into
the keyhole slot (shown in section 3.0 Battery Installation) on the
back of your controller. To secure the controller, drive other screws
through the holes (shown in section 3.0 Battery Installation) in back.
Use wall anchors or toggle bolts if wall is hollow. CAUTION: Do not
connect to electricity until after valves are connected, see sections
6.0 and 7.0.
|
|
| 5.0 Outdoor Model Installation |
|
|
Installing the Outdoor Model Controller
Use the mounting template to locate the 3 mounting holes. Although you
can locate your outdoor model almost anywhere, it is best to avoid direct
exposure to spinkler spray. Since this device is "hard wired," keep in mind
that you must run electrical cable to it. NOTE: Be sure that the ground
wire is connected and that the controller is not sharing the same circuit as
a large applicance. Open the door to your controller, then pop the control
module up by flexing the inside tabe to your right. Locate your controller
over the area you marked with the template, then drive 3 screws through the
holes provided. Use wall anchors, toggle bolts or other appropriate fasteners
when attaching to other that wall studs. Insert a battery, see section 3.0.
CAUTION: Do not connect to electricity until after valves are connected,
see sections 6.0 and 7.0.
|
|
| 6.0 Connecting the Valves |
|
|
Connecting the Valves
CAUTION: Before connecting the valves to the controller make sure that
it is unplugged (indoor model) or disconnected from power (outdoor model).
Open the inside door the same way in which you installed the battery. Route
each valve lead wire through the hole in the bottom (use the left-hand hole on
the outdoor model) to the desired numbered terminal, see section 7.0. Attach
the ground wire from each valve to a single common wire and attach that wire
CAUTION: Before connecting the valves to the controller make sure that
it is unplugged (indoor model) or disconnected from power (outdoor model).
Open the inside door the same way in which you installed the battery. Route
each valve lead wire through the hole in the bottom (use the left-hand hole on
the outdoor model) to the desired numbered terminal, see section 7.0. Attach
the ground wire from each valve to a single common wire and attach that wire
to the "COM/GRD" terminal. Use the chart in section 13.0 to note which valve
is operated by which numbered terminal.
NOTE: This controller is designed to work with 24 VAC, 5VA solenoid operated
valves. A maximum of 2 solenoids per terminal may be used, and no more than 5
solenoids should be on at any one time. This includes the master valve and/or
pump start, if one is being used. Current requirements should not exceed .25
amp. (6VA) for any solenoid.
Connecting a Master Valve or Pump
To use a master valve which operates throughout the watering cycle, connect
your lead to the "MV" terminal and the ground to "COM/GRD." NOTE: The master
valve must be equipped witha 24 VAC, .2 amp., 5VA solenoid. The controller
should not be installed within 5 feet of a pump or pool equipment.
To use a pump, connect to the "MV" and "COM/GRD" terminals as described
above. The pump relay should have a nominal coil voltage of 24 VAC at .25
amp. maximum.
CAUTION: If you are using a pump start circuit, the fail-safe
program will activate the pump for all valves for 10 minutes each on Prog. A
only. If all valves are not being used, the pump will run against a "dead heat"
on each unused valve. This can damage the pump. To avoid this, simply connect
a jumper wire from the unused valve terminal to a valve terminal that is in use.
|
|
|
|
|
Indoor Model: After you have completed all valve connections
and have a stable controller installation, route the two leads from your
transformer through the bottom hole and connect to the 24 VAC INPUT terminals,
then snap the control module closed. Plug the transformer into a standard 120
volt outlet. A flashing "12:00 PM" should show on the display.
Outdoor Model: Outdoor controllers have a built-in transformer which
must be connected directly to a grounded, 3-wire, 120 VAC power source. This
connection should be made by a licensed electrical contractor in accordance with
all requirements of the National Electrical Code and applicable state and local
codes. NOTE: Local building and electrical codes usually require that
approved electrical conduit and fittings be used to connect exterior, wall-mounted
equipment to 120 VAC power. CAUTION: DO NOT connect the contrller to one
phase of a 3-phase power system used by a pump or other electrical equipment.
To connect to an outdoor model controller, complete the following:
1. Turn of installation site power at the associated circuit breaker.
2. Verify that power has been turned off at the installation site by using an
appropriate AC voltage meter.
3. Install the conduit and associated fittings.
4. Connect power and ground wires per electrical codes.
5. Turn power on.
6. Check controller operation. If the controller is not operating, unplug
the transformer and check for shorts.
|
|
|
| 8.0 What the Buttons and Switches Do |
|
|
Program Switch
... used to set up to different programs for automatic operation, or to
select a pre-set program (A, B or C) for semi-auto operation. After use
in either mode, switch position does not affect daily automatic operation.
Function Switch
... Set to the left, it stops a programmed watering cycle and any valves
that are on. In this mode, all programs are retained and the clock
continues. Watering will not resume until the switch is returned to
"RUN." Set to the left when it rains.
... Set in the middle, the switch enables the user to set new programs,
or change existing ones.
... Set to the right for normal, daily automatic operation.
Semi-Auto Start Button
... Used with Program Switch. When depressed, immediately starts program
selected (A, B or C) regardless of automatic program cycle.
Manual Start Button
... Used with Multi-Function Dial and +/- Buttons. When depressed, operates
any selected single valve for an amount of time selected by user.
Multi-Function Dial
... Use with Manual Start Button for single valve operation.
... Use to set, check or change program information in conjuction with
Number Advance Buttons. After using, always return dial to "Current Time."
+/- Buttons
... Use with Multi-Function Dial or in Manual Mode to set or change program
information. Single finger taps to either button advance or reduce data one
character at a time. Holding either button down advances at a rate of 12 characters/sec.
LCD Display
... Shows current operation
|
|
| 9.0 How the Multi-Function Dial Works |
|
|
"Valve Run Time" Settings
These settings control how long each valve will water. The valve numbers
correspond to the numbered terminals in back of the controller. The valves run
sequentially; when one stops, another begins. You can set each valve to run
from 1 minute to 5.9 hours.
"Start Times" Settings
Up to 3 different start times (time of day) can be selected for each program, up
to 9 start times per day. These settings are especially useful for newly seeded
lawns. NOTE: If a program from one day impinges on another program the
next day, the controller will finish the first program.
"Schedule" Day Settings
Select which days watering is to occur by designating particular days of the week
(for example, watering every Monday and Thursday), or setting skip day
intervals (e.g. watering every 4 days). Days in either mode can be programmed "off."
"Today" Setting
This setting is used with the skip day schedule. For example, if you want to
water every 8 days, and you watered 4 days ago, you would enter the number
4 in the Today setting so that in 4 more days, your newly programmed watering
cycle will begin.
|
|
| 10.0 "Anywhere" Programming, Fail-Safe Mode |
|
|
Anywhere Programming
The Rain Dial control module is designed to be easily removed for complete
programming in a more convenient setting, or service. The module's battery
power holds the program until the module is re-electrified. To remove the
module, pop the module up as if you were going to replace the battery. Note
the multi-pin plug on the upper left-hand face of the terminal board. Grasp the
"wiring harness" closest to the plug and pull it out from the terminal. Then
unsnap the module from the 2 hinge points. After programming or servicing,
reinstall the module by reversing the steps above.
Fail-Safe Mode
If the battery fails during a power interuption, your program will be lost. When
power is restored, the Rain Dial controller automatically defaults to its fail-safe
mode. Upon restoration of power, the fail-safe mode returns to Sunday at
12:00 p.m. and the clock runs from that point. Unless the controller is reprogrammed,
it will run each valve for 10 minutes, beginning at 7:00 a.m. These
10 minute waterings are repeated every 24 hours. This feature is designed to
protect lawns and plants from drying out from outages that occur while you are
away for a prolonged period of time. NOTE: In freeze areas, disconnect the
controller while you are away to prevent activation of the fail-safe program.
|
|
| 11.0 Automatic Operation, Step-By-Step |
|
|
Select Valve Watering Times
1. Set Program Switch to "A"
2. Move Function Switch to "Set Programs"
3. Turn dial to valve number 1. Use the +/- buttons to enter how long the valve is to water.
4. Repeat step 3 for valve number 2, valve number 3 and so on. Use the +/-
buttons to set unused valves to "Off."
Repeat the above steps if you wish to use Programs "B" and "C."
Dial in Start Time(s)
1. Turn dial to "1st Start Time." Use the +/- buttons to enter the time when you want Program "A" to start.
2. If you want Program "A" to water more than once a day, turn the dial to 2nd Start Time. Repeat
step 1 to enter a second time, or press "-" for off. Repeat for 3rd Start Time. To
shut off start time, press the "+" button until you reach 11:59 PM. Then press "+" button
once more to display "Off."
|
Repeat the above steps if you wish to use Programs "B" and "C."
Dial in Daily Schedule
First, decide whether you want to use the controller's daily schedule (for
example, water every Monday, Wednesday and Friday) or the interval "Skip Days"
schedule (to water every third day, for example, set at 3) to activate your watering cycle.
|
|
Daily Schedule
Dial in Sunday. Use the +\- buttons for "On" or "Off." Repeat this procedure
for each succeeding day of the week. NOTE: When using this schedule, be sure
to set the "Skip Days" setting to "Off."
"Skip Days" Schedule
1. Turn dial to "Skip Days." Use the +/- buttons to set the desired
daily interval (for example, once every 8 days.)
2. Turn the dial to "Today." Use the +\- buttons to set which day in the
cycle "Today" should be, see section 9.0.
Repeat teh above steps if you wish to use Programs "B" and "C."
Set the Clock
1. Turn dial to "Current Time." With the Function Switch still in the "Set Programs"
position, use the +\- buttons to set the current time.
2. Turn the dial to "Today." Use the +\- buttons to select the current day.
3. Return the dial to "Current Time."
Activate the Controller
Activate the programming you have just entered by moving the Function Switch
to the "Run" setting.
How to Check Your Program
Move the Fucntion switch to "Off" and move the Program Switch to whichever
program you wish to check, then turn the dial to the parameter you want to
check. With the Function switch in the "Off" position, you can check, but you
cannot change the programming.
|
|
| 12.0 What the LCD Displays Mean |
|
|
Information Displayed When Programming
The LCD will display these kinds of data with the Function switch in the "Set
Programs" position, in conjunction with the following dial settings:
Valve Run Times
Shows minutes (e.g., 15 MIN) or hours (e.g., 1.5 HOUR). Also displays "OFF" for unused valves.
Start Times
Displays time in AM, PM, or OFF for unused start times.
Skip Days
Shows days numbered 1-15, or OFF. The words, "ONCE EVERY" appear to the left.
Schedule
Displays ON or OFF. If "Skip Days" has been set, 3 dashes (---) and the words,
"SKIP MODE" will be displayed for each of the 7 daily settings.
Today
Displays 7 individual days for a weekly schedule, or displays day interval numbers
(1-15) for a "Skip Days" schedule.
|
|
Information Displayed When Operating
With the Function switch in the "Run" position, and the dial set to "Current Time,"
the number of any valve that is on will be displayed.
Automatic Mode with No Program On
With the Function switch in the "Run" position, the current
time with a flashing colon (:) is displayed. If the entire display
is flashing, the controller has just been plugged in or there has
been a power outage. If the colon is not flashing, the controller
is using battery power.
|
|
Automatic or Semi-Auto Mode With Program On
Shows the current time. Turn the dial to a valve that is on, and the
display will show the valve number, the program (A, B or C) and the time
remaining for the valve to run. If you turn the dial to a valve that is
not currently on, the display shows "OFF" (even though that valve may have
a programmed run time.)
|
|
Manual Mode
With the dial pointing to the appropriate valve, the display shows the valve's
number, an "M" (for manual mode), and the time remaining for the valve to run.
|
|
Short / Malfunction Detection
A flashing "OFF" indicates that the dial is pointing to a valve that has a
short or other electrical malfunction.
|
|
NOTE: After a power outage or when the controller is energized,
the display will flash 12:00 PM (or the current time if it was a short
outage.) Stop the flashing by pressing either of the +\- buttons.
|
|
| 13.0 Documenting Your Auto Operation |
|
|
Use this chart to note your valve locations and their corresponding numbers.
Use this chart to document your auto operation.
Watering Considerations
Plants, soils and climatological conditions vary from region to region. Consult
your local nursey for the watering schedule best suited to your particular requirements. As
a general rule, the best time to water is early morning because evaporation, wind drift and
temperature are minimal. Evening watering may promote mildew and fungus growth.
|
|
| 14.0 Semi-Auto and Manual Operation |
|
|
Semi-Auto Operation...
Runs an entire program (A, B or C) whenever you want a supplemental watering.
1. Make sure the Function switch is in the "Run" position and the dial points to "Current Time."
2. Use the Program switch to select the program (A, B or C) you want to run.
3. Press the Semi-Auto Start button.
The display will show whichever valves are on in the program you have selected. When
the semi-auto cycle is complete, the controller will resume its regular schedule.
Manual Operation...
Runs a single valve for the amount of time you select.
1. Make sure the Function switch is in the "Run" position.
2. Dial in the valve number (1-12) you want to run.
3. Use the +/- buttons to select the amount of time you want to water.
4. Press the manual button.
The display will show an "M" (for manual), the valve number and the time remaining
for that valve to run. When the manual cycle is complete, the controller will
resume its regular schedule. Return the dial to "Current Time."
Manual Shut-Off
To shut valves off, make sure dial points to "Current Time," then move the
Function switch to "Off." Scheduled watering will resume when the Function
switch is returned to "Run."
|
|
| 15.0 Troubleshooting the System |
|
|
How to Check for Valve "Shorts"
Rain Dial controllers are uniquely able to detect and identify valves malfunctioning
due to electrical shorts in their wiring. Use your controller to check any or all
valves with a twist of the dial:
1. Make sure the Function Switch is set to "Run."
2. Turn the dial to the valve you want to check.
3. Use +\- buttons to enter a run time.
4. Press the Manual button.
If the display flashes "OFF," that particular valve has an electrical short
or other problem. The solenoid and field wiring should be inspected. CAUTION:
Do not test valves by touching wire ends to terminal screws. Serious damage
may result.
| PROBLEM |
POSSIBLE CAUSE |
CORRECTION |
| Some valves don't operate. |
Solenoid defective |
Test & replace as required |
| Loose wire connections |
Secure wire connections Check for continuity |
| No valves operate |
Function Switch in "OFF" or "STOP" position |
Set switch to "RUN" or "MANUAL" position |
| Solenoid defective |
Test & replace as required |
| Loose wire connection |
Secure wire connections Check for continuity |
| Day set to "OFF" |
Check current day in display. Set dial to correct day and check setting. |
| "Skip Days" incorrectly set |
Check and reprogram. See section 11.0 |
| "Start Times" set to "OFF" |
Reprogram "Start Times" |
| Watering at wrong times |
"Current Time" of day incorrectly set |
Check and reset "Current Time" |
| "Start Times" incorrectly set |
Check and reset all "Start Times." See section 11.0 |
| Display blank |
No power |
Check circuit breaker panel Check wiring, connections Transformer plugged in? |
| Program won't display |
Wrong function setting |
Function Switch must be in "Run or Manual" setting |
| Controller is in watering cycle |
Check or change program with Function switch in "Set Programs" |
| Incorrect display (After a power outage or after being plugged in.) |
Battery is weak or missing |
Remove AC power and battery for 1 minute. Replace battery, restore power and reprogram |
| Waters on wrong days |
Weekly or "Skip Days" schedule incorrectly set. |
Reprogram. See section 11.0 |
| Display is flashing |
Excessive load |
Check max. ratings, see section 6.0 |
| Shorted solenoid or field wiring |
Check solenoids and wiring, see beginning of this section |
| Valve won't turn off (Function switch "Off") |
Mechanical override. (Manual bleed is on) |
Turn solenoid on top of valve fully clockwise |
|
|
|
|
|
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful intereference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio / TV technician for help.
This equipment has been verified to comply with the limits for a class B computing device, pursuant to FCC Rules. In
order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with
non-approved equipment or shielded cables is likely to result in interference to radio and TV reception. The user is
cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the user's
authority to operate this equipment.
|
|
|
|