15.0 Troubleshooting the System

How to Check for Valve "Shorts"
Rain Dial controllers are uniquely able to detect and identify valves malfunctioning due to electrical shorts in their wiring. Use your controller to check any or all valves with a twist of the dial:
1. Make sure the Function Switch is set to "Run."
2. Turn the dial to the valve you want to check.
3. Use +\- buttons to enter a run time.
4. Press the Manual button.
If the display flashes "OFF," that particular valve has an electrical short or other problem. The solenoid and field wiring should be inspected. CAUTION: Do not test valves by touching wire ends to terminal screws. Serious damage may result.

PROBLEM POSSIBLE CAUSE CORRECTION
Some valves don't operate. Solenoid defective Test & replace as required
Loose wire connections Secure wire connections
Check for continuity
No valves operate Function Switch in "OFF" or "STOP" position Set switch to "RUN" or "MANUAL" position
Solenoid defective Test & replace as required
Loose wire connection Secure wire connections
Check for continuity
Day set to "OFF" Check current day in display. Set dial to correct day and check setting.
"Skip Days" incorrectly set Check and reprogram. See section 11.0
"Start Times" set to "OFF" Reprogram "Start Times"
Watering at wrong times "Current Time" of day incorrectly set Check and reset "Current Time"
"Start Times" incorrectly set Check and reset all "Start Times." See section 11.0
Display blank No power Check circuit breaker panel
Check wiring, connections
Transformer plugged in?
Program won't display Wrong function setting Function Switch must be in "Run or Manual" setting
Controller is in watering cycle Check or change program with Function switch in "Set Programs"
Incorrect display (After a power outage or after being plugged in.) Battery is weak or missing Remove AC power and battery for 1 minute. Replace battery, restore power and reprogram
Waters on wrong days Weekly or "Skip Days" schedule incorrectly set. Reprogram. See section 11.0
Display is flashing Excessive load Check max. ratings, see section 6.0
Shorted solenoid or field wiring Check solenoids and wiring, see beginning of this section
Valve won't turn off (Function switch "Off") Mechanical override. (Manual bleed is on) Turn solenoid on top of valve fully clockwise
 


Product Inquires
P.O. Box 489
Riverside, CA 92502

 

Page : Intro 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
To return to the Interactive Programming Controller - click here



Copyright © 1997-2008 McKEOWN INC. All rights reserved.
No part of this site may be reproduced without express written consent from McKEOWN INC.

If you experience any problems with this site, please contact webmaster@mckeowninc.com.
Site designed and hosted by LandscapeMart.com
RainDial manual Copyright ©1997 Irritrol Systems