4.0 Indoor Model Installation

Installing the Indoor Model Controller
Using the mounting template, locate your Rain Dial indoor model in an area protected from weater - such as a garage - within 5 feet of a standard (120 volt U.S.) electrical outlet. NOTE: Do not install on the same circuit as a high power user such as a refrigerator, garage door opener or air conditioner. Insert a #10 screw into a wall stud, leaving about 1/4" exposed to slip into the keyhole slot (shown in section 3.0 Battery Installation) on the back of your controller. To secure the controller, drive other screws through the holes (shown in section 3.0 Battery Installation) in back. Use wall anchors or toggle bolts if wall is hollow. CAUTION: Do not connect to electricity until after valves are connected, see sections 6.0 and 7.0.

 